Analyzers for rent : Liston  Scientific



NDIR Single Gas Analyzer

Model 300 is designed to measure a single gas. The Model 300 optical bench consists of the IR source, sample cell, and patent pending detector. The source control circuit provides a controlled current square wave to the infrared source. No mechanical chopper is used so there are no moving parts in the Model 300 optical bench that wear out or require adjustment. Infrared energy from the source passes through the sample where energy at specific wavelengths is absorbed by the sample. The closed sample path eliminates interfering absorption from ambient air. The energy not absorbed in the sample cell reaches the detector which is sensitive to the wavelengths attenuated by the gas of interest. The patent pending Model 300 detector consists of two chambers in optical series with a very sensitive transducer to measure the relative energy absorbed by each chamber. The primary difference between the Model 300 detector and other NDIR detectors is that these two signals from the primary and secondary chamber are balanced. The balancing process greatly improves the sensitivity and selectivity for the gas of interest.

Applications

  • Stack gas monitoring
  • Continuous emission monitoring
  • Monitoring of: boilers, incinerators, furnaces

Standard Specifications

Analysis Method NDIR Single Beam
Gas Measured User Selectable
Measuring Range User Selectable
Resolution 0.1% of Full Scale
Repeatability 0.1% of Full Scale
Noise 0.1% of Full Scale
Drift 0.1% of Full Scale
Response Time at 1, 10 or 100
Display Vacuum Florescent, 2 Lines of 16 Alphanumeric Characters
Alarms High & Low Limit, User Selectable
Analog Output Selectable 0-1, 5, 10Volts, Optional Isolated 4-20mA Loop
Analog Ranges 4, Each With Adjustable Full Scale. Selectable Auto Range
Front Panel Four Button Interface, Using Display Menus
Voltage 0-1, 5, 10Volts, Selectable
A.C. Output Isolated Triac Control for Zero & Upscale Gas Values.
Rated Maximum Load: 0.6Amp, 240VAC

Operating Requirements

Power 115/220Vac, 50/60Hz
Power Consumption 200Watts
Sample Flow .2 to 2.0 Liters/Minute
Sample Temperature -10 to +50 Degrees C.
Dust Sample Should be Dust Free
Moisture Non-Condensing (Dew Point Below Outlet Temp. of Analyzer
Pressure Inlet Gas not to Exceed 5PSIG
Exhaust Gas Non-Restrictive Outlet Aperture/Hoses
Zero Gas Typically Nitrogen
Upscale Calibration Gas Gas of Interest in Nitrogen
Warm Up Time Useable in 30 Minutes. Optimum Operation in 2 Hours
Ambient Conditions Operating -10 to 50 Degrees C.
Storage -10 to 80 Degrees C.
Dimensions 22"L x 18"W x 5.25"H
Weight 22LBS